English German

 

Power Supply
Raid Module
Card Reader
 
MRG-6500P Mini Redundant
Peripheral > Power Supply > Zippy > MRG-6500P

 

  • Certificate
  • Structure
    • Output Wattage : 500W
    • Connector Type...
      ATX 2.03, ATX12V(P4), EPS12V, WTX, AMD-GES
    • Best Solution for...
      Server, Workstation, Storage System, IPC
    • Dimension
      200.00 x 150.00 x 86.00 (mm)
      7.87 x 5.91 x 3.39 (inch)
    • Shop: In-Tec
    AC INPUT SPECIFICATION
     
  • VOLTAGE: 90 ~ 264VAC FULL RANGE
  • DC INPUT SPECIFICATION
    OUTPUT VOLTAGE
    OUTPUT CURRENT
    REGULATION
    OUTPUT
    MIN.(A)
    MAX.(A)
    LOAD
    LINE
    RIPPLE & NOISE
    MAX.[P-P]
    +5V
    3
    35
    ± 5%
    ± 1%
    50mV
    +12V
    2
    32
    ± 5%
    ± 1%
    120mV
    -5V
    0.05
    0.8
    ± 10%
    ± 1%
    150mV
    -12V
    0.05
    1.0
    ± 10%
    ± 1%
    150mV
    +3.3V
    1
    25
    ± 5%
    ± 1%
    50mV
    +5VSB
    0.1
    2.5
    ± 5%
    ± 1%
    60mV
    Remarks:
    * TOTAL CURRENT OF +5V & + 3.3V NOT EXCEED 45A, +3.3V & 12V SHOULD NOT EXCEED 50 A;
    * TOTAL MAXIMUM OUTPUT OF 5V, 3.3V AND 12V : 472W

     

    • Active PFC (full range), MEET IEC-1000-3-2 CLASS D
    • 12V Max. Current : 32A
    • TEMPERATURE RANGE : OPERATING 0oC ~ 40oC, STORAGE -20oC ~ 70oC
    • HUMIDITY:OPERATING:20%-95%, NON-OPERATING:10%-95%
    • REMARKS:85% IS NORMAL CONDITION AND 95% IS WITH SPECIAL COATING PROCESS
    • EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
    • SAFETY: MEET UL 1950, CSA 22.2 NO/ 950, TUV IEC 950
    • HOT-SWAPPABLE / HOT-PLUGGABLE REDUNDANCY FUNCTION
    • Cooling: TWO 40 mm DC FANS (MODULE)
    • AC INLET IN EACH MODULE
    • Serial ATA optional
    YANG-iT TECHNOLOGY GmbH   Mühlenhagen 130 20539 Hamburg   Tel : +49 40-780461-0   Fax: +49 40-780461-11