Zippy P2U-6300P 2U Single

Features:

  • Output Wattage: 300W
  • Connector Type: ATX 2.03, ATX12V(P4), EPS12V
  • Best Solution for: Server, Workstation, Storage System, IPC
  • Dimension:
    200.00 x 100.00 x 70.00 (mm)
    7.87x 3.94 x 2.76 (inch)
Categories: , Tag:

Description

Specifications:

AC INPUT SPECIFICATION

  • VOLTAGE: 90 ~ 264VAC FULL RANGE
  • FREQUENCY : 47 ~ 63 HZ
  • INPUT CURRENT: 6.0 A ( RMS ) FOR 115VAC 3.0 A ( RMS ) FOR 230VAC
  • INRUSH CURRENT: 60A MAX. FOR 115 VAC 800A MAX. FOR 230 VAC

DC INPUT SPECIFICATION

OUTPUT VOLTAGE
OUTPUT CURRENT
REGULATION
OUTPUT
MIN.(A)
MAX.(A)
LOAD
LINE
RIPPLE & NOISE
MAX.[P-P]
+5V
3
35
± 5%
± 1%
80mV
+12V
2
16
± 8%
± 1%
120mV
-5V
0.05
0.50
± 10%
± 1%
120mV
-12V
0.05
1
± 10%
± 1%
150mV
+3.3V
1
20
± 5%
± 1%
70mV
+5VSB
0.1
2
± 5%
± 1%
60mV
  • Active PFC (full range), MEET IEC-1000-3-2 CLASS D
  • 12V Max. Current : 16A
  • TEMPERATURE RANGE: OPERATING 0oC ~ 40oC.
  • HUMIDITY:OPERATING:20%-95%, NON-OPERATING:10%-95%
  • REMARKS:85% IS NORMAL CONDITION AND 95% IS WITH SPECIAL COATING PROCESS
  • EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
  • OVER POWER PROTECTION
  • OVER VOLTAGE PROTECTION
  • SHORT CIRCUIT PROTECTOIN
  • SAFETY: UL, CSA, TUV
  • Remote on/off control
  • Cooling: TWO 60 mm DC Fans
  • 3.3V / 5V Remote sensing
  • Serial ATA optional
  • *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.